The SPIRIT-E research project led by the Technical University of Munich (TUM) published its results on Oct 30. A MAN eTGX with 480 kWh of usable energy, at the depot of logistics company Schmid near Regensburg, fed power at up to 350 kW via an SBRS bidirectional DC charger into the depot's internal grid and the public grid, and charged other vehicles. The project estimates that smart scheduling can cut depot energy costs by about 10% on average and by up to 20%. Electricity trading was tested only in a simulated environment; German grid and metering operators must implement new billing rules for bidirectional charging by the end of Sep 2027 at the latest.
The three-year project ended in Oct 2026 and ran as a "real-world laboratory" at a Spedition Schmid logistics depot. All three use cases were demonstrated: powering the depot (V2S), charging another vehicle (V2V) and feeding power into the public grid (V2G). Vehicle-to-charger communication used ISO 15118-20, the standard that defines the information exchange required for bidirectional energy flow.
| Members | Type | Role in the project |
|---|---|---|
| Technical University of Munich (TUM) | Universities | Consortium lead |
| MAN Truck & Bus | OEM | Supplies eTGX test trucks, advancing series-production rollout |
| SBRS(Shell) | Charging equipment | Bidirectional DC charger |
| TenneT | Transmission system operator | Grid side |
| Hubject | Charging interoperability platform | Charging communication and billing interoperability |
| Consolinno Energy | Energy management | Depot energy management |
| Fraunhofer IEE | Research institution | Energy systems research |
| Research Center for Energy Economics (FfE) | Research institution | Energy economics modelling |
| Usage | Where the power goes | Test method |
|---|---|---|
| V2S vehicle-to-site | Depot's internal grid: peak shaving, higher solar self-consumption, support for building power | Real vehicle powers a building overnight |
| V2V (vehicle-to-vehicle) | Charging another vehicle | In practice Truck battery charges an electric car |
| V2G vehicle-to-grid | Feeding the public grid when prices are high, or supporting grid stability | Real vehicle feeds power into the public grid |
| Power trading | Charge when cheap, sell when expensive | Simulated not run as a commercial service |
The project team stresses that the savings are estimates, not guaranteed results. Actual returns depend on electricity prices, annual mileage, depot charging infrastructure, downtime and on-site renewable energy. The researchers consider the best fit to be electric trucks that cover less than 100,000 km a year on regional routes and return to the same depot every day.
| Conditions | Impact on savings |
|---|---|
| Electricity price | The wider the peak/off-peak price gap, the more room for peak shaving and low-cost charging |
| Annual mileage | Applies to vehicles driving under 100,000 km a year |
| Depot charging infrastructure | Requires bidirectional chargers and a depot energy management system |
| Parked time | Time parked at the depot is time when charging can be scheduled |
| On-site renewable energy | With solar, self-consumption share can be raised |
| Applicable vehicles | Regional routes, return to the same depot daily, predictable schedules |
Before the amendment, Germany treated EVs as vehicles, not storage. Drawing power from the grid incurred grid fees and electricity tax, and feeding it back and recharging incurred them again, so V2G electricity was effectively charged twice. The energy law amendment passed by the Bundestag on Nov 13, 2025 exempts electricity that is stored and fed back into the same grid from grid fees and electricity tax. The exemption covers both stationary storage and bidirectional-charging EVs.
| Stage | Before amendment | From 2026-01-01 |
|---|---|---|
| Charging from the grid | Subject to grid fees and electricity tax | No charges on power fed back after storage |
| Fed back to the grid, then recharged | Paid twice | Treated as stored energy; no double charging |
| Role of the EV | Vehicles | Treated the same as stationary storage |
| Metering and billing | No specific rules | MiSpeL: bidirectional chargers treated as storage; operators to implement by end-Sep 2027 |
| Figures | Scope | Source |
|---|---|---|
| 480 kWh | Usable battery capacity of eTGX test vehicle | Sustainable Truck & Van,2026-10-30 |
| 350 kW | Maximum power fed back via SBRS bidirectional DC charger | Sustainable Truck & Van,2026-10-30 |
| Approx. 1.4 hours | 480 ÷ 350: time to fully discharge at maximum power | Conversions on this page |
| About three years · ends 2026-10 | SPIRIT-E project duration | Sustainable Truck & Van,2026-10-30 |
| 8 companies | Total consortium members (incl. TUM, MAN) | IAA Transportation newsroom, 2026-04-28 |
| About 10% / up to 20% | Depot energy cost reduction, project estimate | Sustainable Truck & Van,2026-10-30 |
| 20,000 km | For a vehicle covering 100,000 km a year, the 20% saving expressed as equivalent driving distance | MAN, via Automotive World |
| Under 100,000 km | Annual mileage of eligible vehicles | Sustainable Truck & Van,2026-10-30 |
| 2025-11-13 | Bundestag passes energy law amendment | electrive,2025-11-14 |
| 2026-01-01 | Grid fee reduction takes effect | The Mobility House,2025-11-18 |
| 6–12 months | Time needed for grid operators to adjust their systems | The Mobility House,2025-11-18 |
| About 3% | Smart meter coverage in Germany | The Mobility House,2025-11-18 |
| End of Sep 2027 | MiSpeL implementation deadline | pv magazine,2026-10-02 |
| 1000 A / 750 kW | Scania MCS bidirectional charging demo | IAA Transportation newsroom, 2026-06-02 |
| 3.75 MW | Long-term MCS power ceiling | IAA Transportation newsroom, 2026-06-02 |